Mechanical Ventilator LUFT3
Breathing Apparatus
Place of Origin: Santa Catarina Brazil Work purpose: ICU ventilator Patients range: Adult, pedriatric and neonatal
Interface: Touch screen
Packaging & Delivery
Packaging Detail: Cartoon/Wooden box. 40 kg 45x45x160 cm
Delivery Detail: 15 days
Specifications
Lung Ventilator for ICU
Lung Ventilator for adults, pediatrics and neonates
Lung Ventilator that learns with its user/operator Standard ContentLUFT3
1 equipment
1 articulated arm
1 trolley
1 air filter
1 air hose
1 O2 hose
1 patient circuit
1 test lung
1 touchscreen monitor
2 exhalation valves (1 extra and 1 with the equipment)
1 user manual
1 technical manual
1 proximal flow sensor
1 oxymetry sensor
1 capnography sensor Tech Specs part1 VENTILATION MODES PATIENT RANGE: Adult and Pediatric
* VCV - Volume Controlled Ventilation
* PCV - Pressure Controlled Ventilation
* PRVC - Pressure Regulated Volume Control
* PSV - Pressure Support Ventilation
* CPAP - Continuous Positive Airway Pressure
* NIV - Non-Invasive Ventilation
* SIMV (VCV / PCV) + PSV - Synchronized Intermitent Mandatory Ventilation with Pressure Support
* MMV + PSV - Mandatory Minute Ventilation with Pressure Support
* PSV + Tv - Pressure Support Ventilation with Assured Tidal Volume
* Biphasic Pressure
PATIENT RANGE: Neonatal
* PCV - Pressure Controlled Ventilation
* Continuous Flow
* PSV - Pressure Support Ventilation
* CPAP - Continuous Positive Airway Pressure
* Nasal CPAP
* SIMV (PCV) + PSV - Synchronized Intermitent Mandatory Ventilation with Pressure Support
FEATURES
* Backup Ventilation: PCV or VCV in adult, pediatric and neonatal
Emergency Ventilation
* FiO2: 21 to 100% (electronically regulated on the panel with graphic display monitoring)
* Inspiration Time: 0.10 to 30.0 seconds
* I:E Ratio: 5:1 - 1:99
* Frequency: 1 - 180 cpm (cycles per minute)
* Tidal Volume: 5 - 2500 ml
* Sensibility: 0.2 - 15 l/min (by flow); -0.5 to -15 cmH2O (compensated PEEP)
* PCV: 1 to 80 cmH2O over PEEP (with adjustable “Rise Time”)
* PSV: 0 to 80 cmH2O over PEEP (with adjustable “Rise Time”)
* Inspiration Pressure: 2 to 120 cmH2O
* Rise Time: 5 levels
* Expiration Sensibility: Adjustable from 5 to 80% of the initial flow
* PEEP/CPAP: 0 - 50 cmH2O
* Nebulization: 1 to 20 min. with automatic inspiratory volume compensation
* TGI: Synchronized with the expiration phase
* Inspiratory Flow: In VCV mode: Automatic Adjustment.
In PCV and PSV modes: Up to 180 l/min.
Continuous flow in Neonatology: 2 to 15 l/min.
Inspiration flow in Neonatology: 2 to 30 l/min.
* Base Flow: Off up to 50 l/min.
* Expiratory Flow: Up to 120 l/min.
* Sigh: Cycles per hour, quantity, maximum tidal volume and manual trigger.
* Inspiratory Pause: 0.2 - 2 seconds
* 100% FiO2: Oxygenation for aspiration with synchronized system – 1 to 20 min.
* Flow waveform: Square; 100% Descending ramp; 50% Descending ramp; Sinusoidal; Ascending ramp
* Automatic Air - O2 gas net bypass: In case of failure in one of them, the equipment continues operating normally.
* Inspiratory Pressure Inner Safety Valve: Adjusted in 120 cmH2O
* Regulatory Pressure Valve of Air and O2 input: internally incorporated in the equipment
* Stand by: To hold the set configuration without cycling
* Scales: Automatic updated for vertical and horizontal readings
* Freeze: To hold graphics on the screen while the ventilator keeps working normally
* RS232 signal connector: For external communication to software and signals input
* USB signal connector: For technical service and software update
OUTPUT PARAMETERS MONITORING
* Airway Pressure: Peak, Plateau, Mean, Base (PEEP)
* Inspiratory time
* Exhalation time
* I:E ratio and spontaneous breathings
* Inspiratory pause
* Inspired/exhaled tidal volume (distal/proximal)
* Inspiratory/exhalation peak flow (distal/proximal)
* Dynamic compliance
* Total frequency
* Exhalation time constant
* Graphic indicator of spontaneous and mechanical cycles
* Minute volume (distal/proximal)
* FiO2 concentration
* Compressible volume
* Ti/Ttot relation
* etCO2
* Inspired CO2
* Total leakage
LUNG MECHANICS
* AutoPEEP
* Dynamic/Static compliance
* Static inspiratory/expiratory compliance
* Slow vital capacity
* P0.1 (airway obstruction pressure)
* P-V curve with low flow
* Tobin index
* Stress index
ALARMS
* Inspiratory max/min airway pressure (disconnection of the patient circuit)
* Max/min exhaled tidal volume
* Max/min exhaled minute volume
* Apnea with adjustable time
* Max respiratory frequency
* Max/min PEEP and continous pressure
* Gas supply source (air-oxygen)
* Power outage
* Low battery
* Microprocessor
* Interrupted cycle in pressure modes
* Max/min FIO2
* Inverted I:E ratio
GRAPHICS
* Pressure - time
* Flow - time
* Volume - time
* CO2 - time
* Volume loop - pressure
* Flow loop - volume
* Pressure loop - flow
* CO2 loop - volume
UP TO 24h TENDENCIES
* Peak and base pressure
* Flow
* Tidal volume
* Minute volume
* Frequency
* Dynamic compliance
ALARMS LOG
* Records the last 1000 events
OTHER MENUS
* Menu for indication of hours of use and performed services
* Altitude adjustment
* Language selection
* Audio volume adjustment
Tech Specs Part2SELF-TESTS
* Altitude compensation
* Capture of atmospheric pressure
* Oxygen cell detection
* Verification of hours of use
* Sensors calibration
* Proximal sensor detection and calibration
* Circuit leakage measuring
* Circuit compliance measuring
* Calibration of the exhalation flow sensor
* Calibration of the oxygen cell
* Calibration of the internal flow sensors
* Air and oxygen proportional valves tests
* PEEP control valve tests
* Detection and initialization of the capnograph
OTHER SAFETY CHARACTERISTICS
* Automatic compensation of the gases
* Warning of maintenance need
* Possibility of working without flow sensor
* Possibility of working without proximal sensor
* Possibility of working without oxygen cell